Greetings all:

Further to Marc’s recommendation about data logging equipment and monitoring
environmental conditions.  While the HOBO U series loggers are good, their
RH range is only 25% to 95% over 41° to 131° F.  This means that during the
winter, if the space is heated, you may not know how low the RH actually
goes since the RH trace will flat-line at 25%.  If this is acceptable, then
the U-series loggers are OK to use.  However, if you need to know just how
dry the conditions get and whether you get fluctuations at RH below 25%, I
would recommend using the HOBO Pro-8 loggers which have a range of 0 – 100%
RH.

Wendy Jessup
President and Conservator

Wendy Jessup and Associates, Inc.
Care of Cultural Property
933 North Kenmore Street, Suite 323
Arlington, VA 22201
(703) 522-2801
Fax: (703) 522-2802
www.collectioncare.com

=========================================================
Important Subscriber Information:

The Museum-L FAQ file is located at http://www.finalchapter.com/museum-l-faq/ . You may obtain detailed information about the listserv commands by sending a one line e-mail message to [log in to unmask] . The body of the message should read "help" (without the quotes).

If you decide to leave Museum-L, please send a one line e-mail message to [log in to unmask] . The body of the message should read "Signoff Museum-L" (without the quotes).

ATOM RSS1 RSS2